SVG-5

A digital combo set
Available in four modifications.

Purpose

SVG–5 digital combo set can replace a whole complex of instruments required for measuring low-frequency signals

Functions

  • Sine wave generator
  • Broadband RMS voltmeter
  • Narrowband (selective) RMS voltmeter
  • Frequency meter
  • Waveform monitor
  • Spectrum analyzer

Measured parameters

  • Measurement of root-mean-square AC voltage and frequency of single-ended or differential signals
  • Measurement of AC voltage frequency of single-ended or differential signals
  • Generation of sine waves
  • Visual examination of freeform signals
  • Signal spectrum analysis

Standard scope of supply

  • Digital combo set SVG-5
  • Set of cables
  • Instrument certificate, testing guidance, operation manual
  • Carrying case
 

Technical characteristics

Frequency range 300 Hz … 2.5 MHz
Step 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz
Relative frequency instability ±1 · 10-5 %
Frequency setting error ±4 · 10-5 %  ±1Hz
Output signal level at characteristic impedance termination -40 dB… +14 dB (8 mV … 3.88 V)
Output signal level setting step 1 mV, 10 mV, 100 mV, 1 V (0.1 dB, 1 dB, 10 dB)
Single-ended output impedance 50 Ohm
Differential output impedance 100 Ohm
Level setting relative error ±5 %
Measured signal level range -50 dB … +14 dB
(2.5 mV … 3.88 V)
Input signal frequency range 300 Hz … 2.5 MHz
Level measurement relative error < ±10 %
Single-ended input impedance 50 Ohm, 75 Ohm, 100 Ohm, 600 Ohm, 1 MOhm
Differential input impedance 100 Ohm, 150 Ohm, 200 Ohm, 1200 Ohm, 1 MOhm
Measured signal level range -50 dB… +14 dB (2.5 mV … 3.88 V)
Input signal frequency range 300 Hz … 2.5 MHz
Level measurement relative error ±5 %
Frequency bandwidth at -3 dB 40 Hz, 100 Hz, 1.7 kHz
Single-ended input impedance 50 Ohm
Differential input impedance 100 Ohm
Measured frequency range 30 Hz … 2.5 MHz
Measured signal level range 15 mV…3.88 V
Level measurement relative error ±1 · 10-4 % ±1 Hz
Amplitude scanning range 10 µV…100 V
Time scanning range 5 ns… 1 s
Input signal frequency range 300 Hz … 2.5 MHz
Number of channels 1
Maximum frequency 4 MHz
Scale division interval 5 kHz, 50 kHz, 400 kHz
Dynamic range 60 dB
  • Real-time clock
  • 10 settings in memory for each mode
  • Saves 50 previous measurements in voltmeter mode
  • Continuous work time 8 hours
  • Dimensions: 360 × 380 × 140 mm

Downloads

Passport (394 Kb)
Operation manual (907.2 Kb)